Press button 1 again to open the contact (SILENCE THE ALARM)
Press button 2 to momentarily close the normally open contact (Test Alarm).
Requirement: Receiver must be acceptable for the first signal only no matter how many signals are sent during alarming time. It will receive signal again after reopening.
(Picture 1: original picture)
As for his requirement, we retrofit one kind of our products. We use DC voltage output 1 channel remote controlled switch unit (S1X-DC12 & C-2 ) and PIR. We also provide infrared probe to him. Relay on the receiver has changed for transistor.
Here is the wiring picture.
Please pay attention to the picture he sent to us (original picture above), we make a little change, there are 4 point of wire junction, from the top down, we named them 1,2,3,4. We contact point 2 and 3 inside, so he doesn’t need to contact another wire to point 3 like the original picture. Picture 2 and 3 are material object connection diagram.
(Picture 2)
(Picture 3)
When remote control unit begins to work, the receiver will learn codes from transmitter and PIR.
PS: the receiver can only learn Transmitter and PIR one by one. Do not learn them simultaneously.